Product Description:

The 1090 is a precision portable process calibrator that combines source and measurement functions for thermocouples, PT100s, µV, mV & mA.

As a multifunction instrument the 1090 combines accuracy and durability with simple operation, making it ideal for process plant applications.

Thermocouple Measurement and Simulation

Measure and simulate the temperature and mV characteristics of J, K, T, R, S, B, N and E thermocouples.

 

Cold Junction Compensation

The unit can be operated with or without internal cold junction compensation.

 

PT100 Measurement and Simulation

Based on 0.3850 alpha probe standard. Range is -200°C to 700°C.

 

Measurement and Source (µV, mV, and mA)

Measurement ranges are 0 to +/-30mV and 0 to +/-60mA. Source ranges are 0 to +/-80mV and 0 to +80mA.

 

Temperature Units Selection

The display can be easily changed from °C to °F. The equivalent uV (thermocouples) and ohms (PT100) can also be shown.

 

24V Process Loop Drive Mode

A process loop can be driven at 24V and up to 60mA by selecting the ‘Milliamp Source’ mode and setting it at 60mA (or a lower level if required).

 

Inching (Incrementing/Decrementing)

The unit has a general-purpose inching function. This adjusts the output in fixed increments of temperature (thermocouples only) or voltage or current. The set-up menu gives a the user a choice of three levels of increment i.e. 0.1, 1 or 10 for °C/°F, or 1, 10, or 100 uV/uA for voltage/current. The lowest of these represents the highest setting resolution and provides the most precise control of the output.  This is especially useful for calibrating thermostat controllers that have tight specification on hysteresis.

 

Memory Recall and Step/Auto-Step Functions

Up to 10 values can be stored in the unit’s non-volatile memory and they can be recalled at any time. The user can also manually step through them in sequence using the step key. Continuous stepping (auto-step) is also available at any user selectable rate between 1 & 10 seconds/step.

 

Power is via an internal high capacity rechargeable metal hydride battery that can be recharged from the supplied external mains charger. An auto power-down feature helps conserve battery life by switching off the instrument if inactive for over 5 minutes. This feature can be disabled if not required. The unit is supplied in a robust case with a carrying strap. A pocket for the instruction manual is provided.

 

Product Specification:

TEMPERATURE MEASURE

THERMOCOUPLE TYPE  TEMPERATURE RANGE (°C)         ACCURACY (°C)

J             -200 to 580        0.7

K            -200 to -150

-150 to 750        2.5

0.5

T            -200 to 0

0 to 400              1.5

0.4

R            50 to 400

400 to 1750       3.0

1.5

S            -50 to 100

100 to 1750       3.0

1.5

B            110 to 1000

1000 to 1800     3.5

1.5

N           -100 to 890        0.6

E            -50 to 400          0.4

Resolution         0.1°C or 0.1°F   

TEMPERATURE SİMULATİON

THERMOCOUPLE TYPE  TEMPERATURE RANGE (°C)         ACCURACY (°C)

J             -210 to 150

150 to 1200       0.15

0.3

K            -270 to 190

190 to 1250       0.5

0.4

T            -200 to 150

150 to 400         0.4

0.5

R            -50 to 800

800 to 1750       0.8

2.0

S            -50 to 850

850 to 1750       0.9

2.0

B            100 to 1200

1200 to 1800     2.0

3.0

N           -270 to 260

260 to 1300       0.5

1.0

E            -50 to 1000        0.3

Resolution         0.1°C or 0.1°F   

Note: An additional correction representing the equivalent 1μV should be allowed for stray thermal emf effects (Temperature measure & simulation).

 

PT100 SİMULATİON

14 SET TEMPERATURE POİNTS (°C)         ACCURACY

-100, -50, -20, 0, 20, 50, 100, 200, 300, 400, 500, 600, 700, 800 0.1% of resistance value (typically 0.5 °C)

PT100 MEASURE

RANGE ACCURACY        RESOLUTİON

200 to 700 °C, 2 wire.    0.2% of resistance value (typically 0.7 °C)            0.2°C (or 0.2°F)

MİLLİVOLT MEASURE

RANGE RESOLUTİON     ACCURACY         INPUT RESİSTANCE

0 to +/- 30mV    10μV     0.05% of full scale ±1 digit          100kΩ

MİLLİVOLT SOURCE

RANGE RESOLUTİON     ACCURACY         OUTPUT RESİSTANCE

0 to 8mV            0.5μV   +/- 4μV 10Ω

8 to 80mV          5μV       0.02% of full scale          10Ω

MİLLİAMP MEASURE

RANGE RESOLUTİON     ACCURACY         INPUT RESİSTANCE

0 to 60mA          20μA     0.05% of full scale ±1 digit          0.5Ω

MİLLİAMP SOURCE

RANGE RESOLUTİON     ACCURACY

0 to 8mA            0.5μA   +/-10μA

8 to 80mA          5μA       0.02% of full scale

FURTHER FEATURES AND FUNCTİONS

Inching Three levels of increment, 0.1, 1 or 10 for °C/°F, and 1, 10, or 100 μV/ μA for voltage/current. The lowest of these represents the highest setting resolution and provides the most precise control of the output.

24V Process Loop Drive A process loop can be driven at 24V and up to 60mA by selecting the ‘Milliamp Source’ mode and setting it at 60mA

(or a lower level if required). Max Load Specifications: 300Ω/80mA, 480Ω/50mA, 1.2kΩ/20mA

Memory recall & step    10 memory locations for non-volatile storage of values. Manual & AutoStep, rate adjustable from 1 to 10 sec/step

Cold Junction Compensation     Accuracy 0.2°C. Resolution 0.1°C.

Operating Temperature              -10 to 40°C (15 to 105°F)

Connections      Industry standard 4mm screw terminals

Power   A Ni-MH rechargeable battery pack gives approx. 60 hours continuous use. The mains recharger supplied gives full recharge in 11 hours. To conserve battery life a user inactivity power-down feature is included.

Dimensions       H235 x W150 x D75mm

Weight 1.2kg

Supplied With   Carry case, rechargeable battery pack (installed) with mains charger, and user manual

Optional Extras Calibration certificates traceable NPL and UKAS

Country of Origin           UK

​2017’de kurulan Novatech, elektronik sektöründe mümessillik hizmetleri, kağıt, plastik, lastik ve aluminyum sektörlerinde kalite kontrolü ve otomasyonu konularında danışmanlık ve teknik destek hizmetleri vermektedir.
İLETİŞİM BİLGİLERİ
Adres
Folkart Towers A-Blok Adalet Mah. Manas Bulv. No: 47 B/2601 35530
Telefon
+90 232 532 08 32
E-Posta
info@novatech-control.com